Pressure and Temperature Transmitters


ATM.1ST/T

Features

  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -50…150 °C
  • Operating temperature: -40…125 °C
  • Process temperature: -50…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel

ATM.1ST

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Total Error Band: ≤ ± 0.30 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium
  • Feature: Optional surge (lightning) protection

Customer benefits

  • High precision pressure sensor over the whole temperature range
  • Electronic compensation
  • Modular sensor structure (any process and electrical connections can be combined)
  • Can be ordered in different materials
  • Very short response times

ATM.1ST/Ex

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Total Error Band: ≤ ± 0.30 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium

Customer benefits

  • Various certificates available
  • High precision pressure sensor over the whole temperature range
  • Electronic compensation
  • Modular sensor structure (any process and electrical connections can be combined)
  • Can be ordered in different materials
  • Very short response times

ATM.ECO

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0…70 °C)
  • Materials: Stainless steel

Customer benefits

  • Optimal price-quality ratio
  • Electronic compensation
  • Modular sensor structure (any process and electrical connections can be combined)
  • Can be ordered in different materials
  • Very short response times

ATM.ECO/Ex

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0…70 °C)
  • Materials: Stainless steel

Customer benefits

  • Various certificates available
  • Optimal price-quality ratio
  • Electronic compensation
  • Modular sensor structure (any process and electrical connections can be combined)
  • Can be ordered in different materials
  • Very short response times

ATM

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Modular sensor structure (any process and electrical connections)
  • Manual readjustment of 'span' and 'offset' possible
  • Available with lightning protection
  • Can be ordered in different materials
  • Short response times


ATM/Ex

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Various certificates available
  • Modular sensor structure (any process and electrical connections can be combined)
  • Manual readjustment of 'span' and 'offset' possible
  • Available including lightning protection
  • Can be ordered in different materials
  • Short response times


ATM/F

Features

  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -25…100 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel

Customer benefits

  • Common flanges are available (Milk Flange DIN11851, Clamp)
  • Manual readjustment of 'span' and 'offset' possible
  • Electrical connections are modularly arrangeable


ATM/F/Ex

Features

  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -25…100 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel

Customer benefits

  • Various certificates available
  • Common flanges are available (Milk Flange DIN11851, Clamp)
  • Manual readjustment of 'span' and 'offset' possible


ATM/GR

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Two potential free switches (48 V, 2 A, 60W)
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Materials: Stainless steel, Titanium
  • Feature: Output signal 0…20 mA / 4…20 mA

Customer benefits

  • Pressure sensor with integrated switching contacts
  • Modular sensor structure (any process and electrical connections can be combined)
  • Manual readjustment of 'span' and 'offset' possible
  • Can be ordered in different materials
  • Set points definable


ATM/K

Features

  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…125 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel

Customer benefits

  • Ceramic measuring cell
  • Robust version


ATM/T

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Temperature measuring range: -50…150 °C
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • 2 Output signals (p & T): 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Multi-parameter sensor: pressure and temperature
  • Modular sensor structure (any process and electrical connections)
  • Manual readjustment of 'span' and 'offset' possible
  • Can be ordered in different materials


DTM

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Interface: RS232, RS485
  • Materials: Stainless steel, Titanium

Customer benefits

  • Digital pressure sensor with various interfaces
  • Modular sensor structure (any process and electrical connections can be combined)
  • Can be ordered in different materials


PTM

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable: 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible

Customer benefits

  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Modular sensor structure (any process and electrical connections can be combined)
  • Can be ordered in different materials


PTM/Ex

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible

Customer benefits

  • Various certificates available
  • Scalable pressure ranges and output signals
  • Available with surge (lightning) protection
  • Flexibly applicable pressure sensor
  • Modular sensor structure (Any process and electrical connections Can be combined)
  • Can be ordered in different materials


PTM/RS485

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105% (analog output)
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25…85 °C
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • 2 Output signals (p & T): 4…20 mA
  • Interface: RS485 (Modbus RTU)
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible

Customer benefits

  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Digital and analogue output signal in one sensor
  • Available as multi-parameter sensor (pressure & temperature)
  • Modular sensor structure (any process and electrical connections can be combined)
  • Available with lightning protection
  • Can be ordered in different materials


TM

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

Customer benefits

  • Unreinforced output signal
  • Modular sensor structure (any process and electrical connections can be combined)
  • Manual readjustment of 'span' and 'offset' possible
  • Can be ordered in different materials
  • Short response times



TM/Ex

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

Customer benefits

  • Various certificates available
  • Unreinforced output signal
  • Modular sensor structure (any process and electrical connections can be combined)
  • Can be ordered in different materials
  • Short response times


TS 100

Features

  • Temperature measuring range: -50…150 °C
  • Operating temperature: -25…85 °C
  • Process temperature: -50…150 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel
  • Feature: 850 bar proof pressure

Customer benefits

  • Customised matching of the measuring range
  • Customer specific temperature sensor

Submersible level and temperature transmitters


ATM.1ST/N/T

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -5…80 °C
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium


ATM.1ST/N

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.10 % FS
  • Total Error Band: ≤ ± 0.30 %FS (-5…50 °C)
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Optional surge (lightning) protection

Customer benefits

  • High precision pressure sensor over the whole temperature range
  • Electronic compensation
  • Any process connections available
  • Can be ordered in different materials


ATM.1ST/N/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.10 % FS
  • Total Error Band: ≤ ± 0.30 %FS (-5…50 °C)
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Various certificates available
  • High precision pressure sensor over the whole temperature range
  • Electronic compensation
  • Any process connections available
  • Can be ordered in different materials


ATM.ECO/N

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 % FS
  • Total Error Band: ≤ ± 0.70 %FS (-5…50 °C)
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Optimal price-quality ratio
  • Electronic compensation
  • Any process connections available
  • Can be ordered in different materials


ATM.ECO/N/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 % FS
  • Total Error Band: ≤ ± 0.70 %FS (-5…50 °C)
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Various certificates available
  • Optimal price-quality ratio
  • Electronic compensation
  • Any process connections available
  • Can be ordered in different materials


ATM/N

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Optional surge (lightning) protection

Customer benefits

  • Any process connections available
  • Recalibration possible
  • Available with lightning protection
  • Can be ordered in different materials


ATM/N/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Optional surge (lightning) protection

Customer benefits

  • Various certificates available
  • Optimal price-quality ratio
  • Any process connections available
  • Can be ordered in different materials


ATM/N/T

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Temperature measuring range: -5…80 °C
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • 2 Output signals (p & T): 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Multi-parameter diving probe: pressure and temperature
  • Can be ordered in different materials


ATM/N 19

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Materials: Stainless steel
  • Feature: 19 mm diameter

Customer benefits

  • Small dimensions, suitable for 1'' tubes


ATM/K/N

Features

  • Pressure measuring range: 1…200 mH2O
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -5…50 °C
  • Process temperature: -5…50 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel
  • Feature: Optional surge (lightning) protection

Customer benefits

  • Ceramic measuring cell
  • Robust version


ATM/NC

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 2.0 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: PVDF
  • Feature: Optional surge (lightning) protection

Customer benefits

  • With regard to chemical resistance, a unique sensor on the market
  • High media compatibility thanks to a special PVDF-housing


ATM/NC/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 2.0 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: PVDF
  • Feature: Optional surge (lightning) protection

Customer benefits

  • With regard to chemical resistance, a unique sensor on the market
  • High media compatibility thanks to a special PVDF-housing


DTM/N

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Interface: RS232, RS485
  • Materials: Stainless steel, Titanium

Customer benefits

  • Digital pressure sensor with various interfaces
  • Any process connections available
  • Can be ordered in different materials


PTM/N

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible

Customer benefits

  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Any process connections available
  • Available with lightning protection
  • Can be ordered in different materials


PTM/N/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible

Customer benefits

  • Various certificates available
  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Any process connections available
  • Can be ordered in different materials


PTM/N/RS485

Features

  • Pressure measuring range: 1…250 mH2O
  • Adjustable 1:4 of the nominal range within -5% to +105% (analog output)
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25…85 °C
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • 2 Output signals (p & T): 4…20 mA
  • Interface: RS485 (Modbus RTU)
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible, optional surge (lightning) protection

Customer benefits

  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Digital and analogue output signal in one sensor
  • Available as multi-parameter sensor (pressure & temperature)
  • Any process connections available
  • Available with lightning protection
  • Can be ordered in different materials

PTM/N/SDI-12

Features

  • Pressure measuring range: 5…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25…85 °C
  • Operating temperature: -5…50 °C
  • Process temperature: -5…50 °C
  • Interface: SDI-12 (V1.3)
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration possible, Adjustable units

Customer benefits

  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Any process connections available
  • Available including lightning protection
  • Can be ordered in different materials


MTM/N 10

Features

  • Pressure measuring range: 10…100 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25
  • Operating temperature: -5…50 °C
  • Process temperature: -5…50 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium
  • Feature: Level transmitter with 10 mm diameter, Versions with ATM/N or DL/N 70 possible

Customer benefits

  • Submersible level transmitter with a very small diameter
  • Both passive and active versions can be ordered


TM/N

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

Customer benefits

  • Unreinforced output signal
  • Any process connections available
  • Can be ordered in different materials

TM/N/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

Customer benefits

  • Various certificates available
  • Unreinforced output signal
  • Any process connections available
  • Can be ordered in different materials


Measurement Cell


Transducer

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Output signal: mV
  • Materials: Stainless steel, Titanium, Hastelloy

Customer benefits

  • Distinctly reliable and stable measuring cell
  • Various materials and construction types available


Polynom Transducer

Features

  • Pressure measuring range: 2 bar…100 bar
  • Total Error: ≤ ± 0.2 % rdg (30…100 %FS)
  • Compensation: -40…60 °C
  • Operating temperature: -40…150 °C
  • Output signal: mV
  • Materials: Stainless steel

Customer benefits

  • Distinctly reliable, very precise and piezo-resistive measuring cell
  • Compensation by means of polynomials
  • Various materials and construction types available



Data Loggers / Communication


DL

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -40…85 °C
  • Process temperature: -40…100 °C
  • Interface: RS232
  • Materials: Aluminium (Housing), Stainless steel
  • Feature: Battery operation, Measurement interval 2s…24h, 130'000 Measurement values

Customer benefits

  • Industry data logger exhibiting a good quality-price ratio
  • Various process connections


DL.OCS/N/RS485

Features

  • Pressure measuring range: 0…250 mH2O
  • Total Error: ≤ ± 0.05 % FS (-5...50 °C)
  • Temperature measuring range: -5…80 °C
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Interface: RS485
  • Materials: Stainless steel, titanium
  • Feature: Battery operation, Measurement interval 5s…24h, 500'000 Measurement values

Customer benefits

  • Multi-parameter probe: pressure, temperature and conductivity
  • Can be installed into 2'' piezoelectric tubes


DL/N

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -40…85 °C
  • Process temperature: -5…80 °C
  • Interface: RS232
  • Materials: Aluminium (Housing), Stainless steel
  • Feature: Battery operation, Measurement interval 2s…24h, 130'000 Measurement values

Customer benefits

  • Industry data logger exhibiting a good quality-price ratio
  • Available with miniature probe (MTM/N/10)
  • Various process connections


DL/Ex

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -40…85 °C
  • Process temperature: -40…100 °C
  • Interface: RS232
  • Materials: Aluminium (Housing), Stainless steel
  • Feature: Battery operation, Measurement interval 2s…24h, 130'000 Measurement values

Customer benefits

  • Various certificates available
  • Industry data logger exhibiting a good quality-price ratio
  • Various process connections


DL/N/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -40…85 °C
  • Process temperature: -5…80 °C
  • Interface: RS232
  • Materials: Aluminium (Housing), Stainless steel
  • Feature: Battery operation, Measurement interval 2s…24h, 130'000 Measurement values

Customer benefits

  • Various certificates available
  • Industry data logger exhibiting a good quality-price ratio
  • Available with miniature probe (MTM/N /10)
  • Various process connections


DL/N 70

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -5…50 °C
  • Conductivity measuring range: 20 µS/cm…20 mS/cm
  • Operating temperature: -5…50 °C
  • Process temperature: -5…50 °C
  • Interface: RS485
  • Materials: Stainless steel
  • Feature: Battery operation, Measurement interval 0.5s…24h, 500'000 Measurement values

Customer benefits

  • Multi-parameter probe: pressure, temperature and conductivity
  • Can be installed into 2'' piezoelectric tubes
  • Inundation-resistant battery housing
  • Available with miniature probe (MTM/N/10)
  • Compact version without battery housing (only absolute pressure)


GSM

Features

  • Operating temperature: -20…55 °C
  • Data transfer: GSM
  • Frequency band: 900, 1800/1900 MHz (Triband)
  • Materials: Aluminium (Housing)
  • Feature: Battery operation, 
    Readout time: 36s/1000 Measurement    values

Customer benefits

  • GSM-communication module
  • Can be combined with DL or DL/N/70



Watermanager Solution


DL.WMS/GPRS/R

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -5…80 °C
  • Operating temperature: -5 ... 80 / -5 ... 50 °C (logger)
  • Process temperature: -5…80 °C
  • Radio interface: 433 MHz
  • Data transfer: GSM/GPRS
  • Frequency band: 850/900, 1800/1900 MHz (Quadband)
  • Materials level transmitter: Stainless steel, Titanium
  • Materials logger: Plastic, Stainless steel
  • Feature: Battery operation, 250'000 Measurement values, Measurement interval 2s…12h, Online programmable, Housekeeping data (temperature, humidity, battery voltage)

Customer benefits

  • Integrated water management solution
  • Multi-parameter probe: pressure and temperature
  • Various integrated communication technologies
  • Inundation-resistant communication unit
  • The humidity, temperature and battery lifespan of the device are constantly monitored
  • Can be installed into 2'' piezoelectric tubes
  • Web-based software solution


CÔNG TY TNHH CÔNG NGHỆ HOÀNG PHÚ QUÝ
Address: 519/10 Đường số 10, Phường 8, Quận Gò Vấp, Tp.HCM
Telephone: 84 - 6295 8401  - Mobile: 84-938 400 412
Email: hoaiquyet@hpqtech.com